Lanzamiento Enero 2027

Ensayo controlado aleatorizado2006Financiación no declarada

Wingate performance and surface EMG frequency variables are not affected by caffeine ingestion

Greer F, Morales J, Coles M

Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme · 41 citas

Etiquetas de revisión

Financiación no declarada

Datos neutrales que nuestra revisión registró sobre cómo se hizo este estudio. Describen el método, nunca si nos gusta el resultado.

Cómo se estudió

Diseño
Ensayo controlado aleatorizado (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación no declarada

Publicación

Publicado
2006-10-01 · Appl Physiol Nutr Metab · vol. 31 · número 5 · págs. 597–603
Editorial
NRC Research Press
Citado
71 citas · más que el 81% de estudios similares · 1.5× el promedio de su campo
Referencias
48 trabajos
Acceso
De pago
Áreas de investigación
Coffee research and impacts · Sports Performance and Training · Muscle activation and electromyography studies
Palabras clave
caffeine, ergogenic aids, high-intensity cycling, Wingate test, surface electromyography, vastus lateralis, gastrocnemius, integrated EMG, output power
MeSH
muscle, skeletal, humans, caffeine, placebos, electromyography, exercise, double-blind method, bicycling, adult, male, physical exertion

3 autores

  • Felicia A. Greer🇺🇸California State University, Fresno
  • Jacobo O. Morales🇺🇸California State University, Fresno
  • MICHAEL G. H. COLES🇺🇸California State University, Fresno

Resumen

El texto original del estudio, en el idioma en que se publicó.

The ergogenic effect of caffeine and its mechanism of action on short-term, high-intensity exercise are controversial. One proposed mechanism is caffeine's stimulatory effect on the central nervous system and thus, motor-unit excitation. The latter is non-invasively determined from surface electromyographic signal (EMG) frequency measures. The purpose of this study was to determine if power output and surface EMG frequency variables during high-intensity cycling were altered following caffeine ingestion. Eighteen recreationally active college males (mean +/- SD age, 21.5 +/- 1.8 y; height, 181.8 +/- 0.5 cm; body mass, 84.7 +/- 11.4 kg) performed the Wingate test (WG) after ingestion of gelatin capsules containing either placebo (PL; dextrose) or caffeine (CAFF; 5 mg/kg body mass). The trials were separated by 1 week and subjects were asked to withdraw from all caffeine-containing products for 48 h before each trial. From the resulting power-time records, peak power (PP; highest power output in 5 s), minimum power (MP; lowest power output in 5 s), and the percent decline in power (Pd) were calculated. Surface EMG records of the right vastus lateralis (VL) and the gastrocnemius (GA) muscles corresponding to the PP and MP periods were collected and used to determine the integrated electromyogram (IEMG), the mean (MNPF), and the median (MDPF) of the signal's power spectrum. A 2-way repeated measures analysis of variance (ANOVA) (treatment x time) was conducted to determine the effect of caffeine on these variables across levels of time. Caffeine ingestion had no effect on PP (PL, 1049 +/- 192 W; CAFF, 1098 +/- 198 W), MP (PL, 762 +/- 104 W; CAFF, 802 +/- 124 W), or the Pd (PL, 47% +/- 8.9%; CAFF, 48.2% +/- 7.3%) compared with the placebo. For both muscles, MNPF and MDPF diminished significantly (p < 0.001) across time and to a similar degree in both the CAFF and PL trials. Regardless of muscle, CAFF had no effect on the percent change in IEMG from the first 5 s to the last 5 s. For both treatments, the GA displayed a significantly (p < 0.05) greater pre vs. post percent decline in the EMG signal amplitude compared with the VL. These results indicate that caffeine does not impact power output during a 30 s high-intensity cycling bout. Furthermore, these data suggest that caffeine does not impact the neuromuscular drive as indicated by the similar IEMG scores between treatments. Similarly, caffeine does not seem to impact the frequency content of the surface EMG signal and thus the nature of recruited motor units before and after the expression of fatigue. The lack of decline in the IEMG in the VL despite the decline in power output over the course of the WG suggests a peripheral as opposed to a neural mechanism of fatigue in this muscle. The significant difference in the pre vs. post percent decline in the GA IEMG score further supports this notion. The pre vs. post decline in the IEMG noted in the GA may suggest a fatigue-triggered change in pedaling mechanics that may promote dominance of knee extensors with less reliance on plantar flexors.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.