Lanzamiento Enero 2027

Ensayo controlado aleatorizado2006Financiación no declarada

Creatine supplementation does not impair the thermoregulatory response during a bout of exercise in the heat

Weiss BA, Powers ME

The Journal of sports medicine and physical fitness · 12 citas

Etiquetas de revisión

Financiación no declarada

Datos neutrales que nuestra revisión registró sobre cómo se hizo este estudio. Describen el método, nunca si nos gusta el resultado.

Cómo se estudió

Diseño
Ensayo controlado aleatorizado (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación no declarada

Publicación

Publicado
2006-12-01 · J Sports Med Phys Fitness · vol. 46 · número 4 · págs. 555–63
Editorial
National Institutes of Health
Citado
19 citas · más que el 69% de estudios similares · 0.6× el promedio de su campo
Referencias
0 trabajos
Acceso
De pago
Áreas de investigación
Thermoregulation and physiological responses · Muscle metabolism and nutrition · Exercise and Physiological Responses
Palabras clave
creatine supplementation, thermoregulation, exercise in the heat, core body temperature, sweat loss, total body water, hydration, heat stress, heart rate, blood pressure
MeSH
body water, humans, creatine, body temperature, exercise, analysis of variance, body temperature regulation, blood pressure, heart rate, time factors, dietary supplements, adult, male, hot temperature

2 autores

  • Bernard Weiss🇺🇸Culver Stockton College
  • M E Powers

Resumen

El texto original del estudio, en el idioma en que se publicó.

Aim

The aim of this work was to examine the effects of creatine (Cr) supplementation on resting body water volumes and on core temperature and sweat loss during a bout of exercise in a warm environment.

Methods

Twenty-four aerobically trained male subjects (age 22.93+/-3.01 years, height 179.52+/-7.28 cm, mass 82.06+/-14.32 kg) volunteered to participate in this study. Each subject was assessed for resting body water volumes and for body mass (BM), heart rate (HR), blood pressure (BP), and core temperature immediately before and following a 60-min bout of exercise in a warm environment. Core temperature, HR, and BP were also recorded at 10-min intervals during exercise. Subjects were then randomly assigned to either a Cr or placebo (P) group. Each subject returned following a 5-day supplementation period and was reassessed using identical testing procedures. BM was measured using a standard electronic scale. Body water volumes were assessed using a multi-frequency BIS (Xitron Technologies, San Diego, CA, USA). Core body temperature was measured using a CorTemp Disposable Temperature Sensor and a CT2000 Miniaturized Ambulatory Recorder (HTI Technologies, Inc., Palmetto, FL, USA).

Results

The Cr group experienced a significant increase in all body water volumes. No changes were observed in the P group. No changes in core temperature or sweat loss were observed in either group following supplementation.

Conclusions

Cr loading did not impair the thermoregulatory response during a bout of exercise in the heat.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.