Lanzamiento Enero 2027

Ensayo controlado aleatorizado2011Financiación no declarada

Low-level laser therapy of dentin hypersensitivity: a short-term clinical trial

Orhan K, Aksoy U, Can-Karabulut DC, Kalender A

Lasers in medical science · 47 citas

Etiquetas de revisión

Financiación no declarada

Datos neutrales que nuestra revisión registró sobre cómo se hizo este estudio. Describen el método, nunca si nos gusta el resultado.

Cómo se estudió

Diseño
Ensayo controlado aleatorizado (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación no declarada

Publicación

Publicado
2010-06-29 · Lasers Med Sci · vol. 26 · número 5 · págs. 591–598
Editorial
Springer Science+Business Media
Citado
72 citas · más que el 89% de estudios similares · 2.9× el promedio de su campo
Referencias
26 trabajos
Acceso
De pago
Áreas de investigación
Laser Applications in Dentistry and Medicine · Dental Erosion and Treatment · Endodontics and Root Canal Treatments
Palabras clave
dentin hypersensitivity, low-level laser therapy, diode laser, dentin desensitizing agents, glutaraldehyde, cervical dentin, dental pain, visual analogue scale
MeSH
humans, dentin sensitivity, glutaral, pain measurement, time factors, adult, middle aged, female, male, lasers, semiconductor, young adult, dentin desensitizing agents, low-level light therapy

4 autores

  • Kaan Orhan🇹🇷Ankara University
  • Umut Aksoy🇨🇾Near East University
  • Deniz C. Can-Karabulut🇨🇾 · autor de correspondenciaNear East University
  • Atakan Kalender🇨🇾Near East University

Resumen

El texto original del estudio, en el idioma en que se publicó.

The aim of this study was to evaluate low-level laser therapy in cervical dentin hypersensitivity. A randomized controlled clinical trial was conducted with a total of 64 teeth. Dentin desensitizer and diode laser were applied on the cervical dentin surfaces. Distilled water and placebo laser was used as the placebo groups. The irradiance used was 4 J/cm(2) per treatment site. The baseline measurement of hypersensitivity was made by using visual analog scale (VAS). Twenty-four hours and 7 days after the application of desensitizer, diode laser and placebo groups, a new VAS analysis was conducted for the patients' sensitivity level. The mean pain scores of placebo groups were significantly higher than the desensitizer's and diode laser's mean scores (ANOVA, p 0.05). Although low-level laser and glutaraldehyde containing desensitizer present distinct modes of action, experimental agents caused a significant reduction of dentin hypersensitivity without showing secondary effects, not irritating the pulp or causing pain, not discoloring or staining the teeth, and not irritating the soft tissues at least for a period of 1 week with no drawbacks regarding handling and/or ease of application. Low-level laser therapy and desensitizer application had displayed similar effectiveness in reducing moderate dentin hypersensitivity.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.