Caffeine augmentation of ECT
Coffey CE, Figiel GS, Weiner RD, Saunders WB
The American journal of psychiatry · 47 citas
Cómo se estudió
- Diseño
- Ensayo controlado aleatorizado (indexado por PubMed)
- Estudiado en
- Personas
- Resultado principal
- Marcadores de salud y funcionamiento
Quién lo pagó
- Financiación
- Financiación independiente
- Gobierno
- National Institute of Mental Health
- Gobierno
- NIMH NIH HHS
- Subvenciones
- National Institute of Mental Health (MH-41803); National Institute of Mental Health (MH 40159); National Institute of Mental Health (MH30723)
Según 2 financiadores declarados.
Publicación
- Publicado
- 1990-05-01 · Am J Psychiatry · vol. 147 · número 5 · págs. 579–585
- Editorial
- American Psychiatric Association
- Citado
- 102 citas · más que el 98% de estudios similares · 8.2× el promedio de su campo
- Impacto
- Entre el 10 % más citado de su campo
- Referencias
- 23 trabajos
- Acceso
- De pago
- Áreas de investigación
- Electroconvulsive Therapy Studies · Transcranial Magnetic Stimulation Studies · Treatment of Major Depression
- Palabras clave
- caffeine, electroconvulsive therapy, seizure duration, stimulus intensity, depression, cognitive side effects, drug augmentation
- MeSH
- humans, caffeine, placebos, premedication, pilot projects, double-blind method, depressive disorder, electroconvulsive therapy, adult, aged, middle aged, female, male, randomized controlled trials as topic, outcome and process assessment, health care
4 autores
- C. Edward Coffey🇺🇸Duke Medical Center
- Gary S. Figiel
- Richard D. Weiner
- W. Brian Saunders
Resumen
El texto original del estudio, en el idioma en que se publicó.
In a randomized, double-blind, placebo-controlled pilot study of 40 depressed inpatients, the authors compared two techniques for maintaining seizure duration during pulse unilateral ECT: pretreatment with intravenous caffeine versus electrical stimulus intensity dosing. Both techniques effectively maintained seizure duration, but with caffeine this was accomplished without any increase in mean stimulus intensity over the course of ECT. There were no differences between the two techniques in therapeutic outcome or cognitive side effects from ECT, and caffeine pretreatment was well tolerated. The authors discuss the clinical and research implications of these findings with respect to strategies for maintaining seizure duration during ECT.
Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.
Confianza de la comunidad
Cargando…
¿Cuánto confías en los hallazgos de este estudio?
Comentarios
¿Algo está mal aquí?
Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.
Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.