Lanzamiento Enero 2027

Ensayo controlado aleatorizado2014Financiado por la industria

Financiado en parte por Metabolic Technologies

Effects of β-hydroxy-β-methylbutyrate free acid and cold water immersion on post-exercise markers of muscle damage

Gonzalez AM, Stout JR, Jajtner AR, Townsend JR, Wells AJ, Beyer KS, Boone CH, Pruna GJ, Mangine GT, Scanlon TM, Bohner JD, Oliveira LP, Fragala MS, Hoffman JR

Amino acids · 28 citas

Etiquetas de revisión

Financiado por la industria

Datos neutrales que nuestra revisión registró sobre cómo se hizo este estudio. Describen el método, nunca si nos gusta el resultado.

Cómo se estudió

Diseño
Ensayo controlado aleatorizado (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiado por la industria
Empresa
Metabolic Technologies

Según 1 financiador declarado.

Publicación

Publicado
2014-03-18 · Amino Acids · vol. 46 · número 6 · págs. 1501–1511
Editorial
Springer Science+Business Media
Citado
38 citas · más que el 92% de estudios similares · 3.6× el promedio de su campo
Impacto
Entre el 10 % más citado de su campo
Referencias
43 trabajos
Acceso
Acceso abierto (copia en repositorio)
Áreas de investigación
Exercise and Physiological Responses · Muscle metabolism and nutrition · Muscle and Compartmental Disorders
Palabras clave
beta-hydroxy-beta-methylbutyrate, cold water immersion, exercise-induced muscle damage, resistance training, creatine kinase, myoglobin, C-reactive protein, interleukin-6, IL-10, post-exercise recovery, performance recovery, lower body exercise
MeSH
muscle, skeletal, humans, water, valerates, c-reactive protein, myoglobin, exercise, male, cold temperature, young adult

14 autores

  • Adam M. Gonzalez🇺🇸University of Central Florida
  • Jeffrey R. Stout🇺🇸 · autor de correspondenciaUniversity of Central Florida
  • Adam R. Jajtner🇺🇸University of Central Florida
  • Jeremy R. Townsend🇺🇸University of Central Florida
  • Adam J. Wells🇺🇸University of Central Florida
  • Kyle S. Beyer🇺🇸University of Central Florida
  • Carleigh H. Boone🇺🇸University of Central Florida
  • Gabriel J. Pruna🇺🇸University of Central Florida
  • Gerald T. Mangine🇺🇸University of Central Florida
  • Tyler C. Scanlon🇺🇸University of Central Florida
  • Jonathan D. Bohner🇺🇸University of Central Florida
  • Leonardo Oliveira🇺🇸University of Central Florida
  • Maren Susan Fragala🇺🇸University of Central Florida
  • Jay R. Hoffman🇺🇸University of Central Florida

Resumen

El texto original del estudio, en el idioma en que se publicó.

The aim of the current study was to examine the effects of cold water immersion (CWI) with and without the free acid form of β-hydroxy-β-methylbutyrate (HMB-FA) on markers of muscle damage following acute lower body resistance exercise. Forty recreationally resistance-trained men (22.3 ± 2.4 years) were randomly divided into one of the four groups: (1) Placebo (PL); (2) HMB-FA; (3) HMB-FA-CWI; (4) PL-CWI. HMB-FA groups ingested 3 g day(-1) and CWI groups submersed their lower body into 10-12 °C water for 10-min post-exercise. No differences between groups were observed for CK; however, PL-CWI had significantly greater elevations in myoglobin 30-min post-exercise compared to HMB-FA (p = 0.009) and PL (p = 0.005), and HMB-FA-CWI was significantly greater than HMB-FA (p = 0.046) and PL (p = 0.028). No differences between groups were observed for IL-6 and IL-10, although CRP was significantly greater 24-h post-exercise for PL-CWI compared to HMB-FA-CWI (p = 0.02) and HMB-FA (p = 0.046). Only HMB-FA-CWI showed significantly (p = 0.02) greater improvements in average power per repetition. CWI appeared to elevate myoglobin compared to other groups, while HMB-FA may have attenuated the increase in CRP when combined with CWI. Nevertheless, HMB-FA or CWI treatments did not appear to provide benefit over PL for recovery. Instead, the combination of CWI and HMB-FA improved performance recovery compared to other groups.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.