Lanzamiento Enero 2027

Estudio de cohortes2017Financiación no declarada

Cold-Water Immersion Cooling Rates in Football Linemen and Cross-Country Runners With Exercise-Induced Hyperthermia

Godek SF, Morrison KE, Scullin G

Journal of athletic training · 7 citas

Etiquetas de revisión

Financiación no declarada

Datos neutrales que nuestra revisión registró sobre cómo se hizo este estudio. Describen el método, nunca si nos gusta el resultado.

Cómo se estudió

Diseño
Estudio de cohortes (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación no declarada

Publicación

Publicado
2017-09-22 · J Athl Train · vol. 52 · número 10 · págs. 902–909
Editorial
National Athletic Trainers' Association
Citado
12 citas · más que el 64% de estudios similares · 0.4× el promedio de su campo
Referencias
46 trabajos
Acceso
Acceso abierto (copia en repositorio)
Áreas de investigación
Thermoregulation and physiological responses · Climate Change and Health Impacts · Infrared Thermography in Medicine
Palabras clave
Context (archaeology), Animal science, Lean body mass, Athletes, Body mass index, Body surface area, Medicine, Physical therapy, Surgery, Body weight, Internal medicine, Biology
MeSH
humans, fever, water, cohort studies, immersion, body temperature regulation, running, football, adult, female, male, cold temperature, young adult

3 autores

  • Sandra Fowkes Godek🇺🇸West Chester University
  • Katherine E. Morrison🇺🇸West Chester University
  • Gregory Scullin🇺🇸Lehigh University

Resumen

El texto original del estudio, en el idioma en que se publicó.

Context

Ideal and acceptable cooling rates in hyperthermic athletes have been established in average-sized participants. Football linemen (FBs) have a small body surface area (BSA)-to-mass ratio compared with smaller athletes, which hinders heat dissipation.

Objective

To determine cooling rates using cold-water immersion in hyperthermic FBs and cross-country runners (CCs).

Design

Cohort study.

Setting

Controlled university laboratory.

Patients or other participants

Nine FBs (age = 21.7 ± 1.7 years, height = 188.7 ± 4 cm, mass = 128.1 ± 18 kg, body fat = 28.9% ± 7.1%, lean body mass [LBM] = 86.9 ± 19 kg, BSA = 2.54 ± 0.13 m2, BSA/mass = 201 ± 21.3 cm2/kg, and BSA/LBM = 276.4 ± 19.7 cm2/kg) and 7 CCs (age = 20 ± 1.8 years, height = 176 ± 4.1 cm, mass = 68.7 ± 6.5 kg, body fat = 10.2% ± 1.6%, LBM = 61.7 ± 5.3 kg, BSA = 1.84 ± 0.1 m2, BSA/mass = 268.3 ± 11.7 cm2/kg, and BSA/LBM = 298.4 ± 11.7 cm2/kg).

Intervention(s)

Participants ingested an intestinal sensor, exercised in a climatic chamber (39°C, 40% relative humidity) until either target core temperature (Tgi) was 39.5°C or volitional exhaustion was reached, and were immediately immersed in a 10°C circulated bath until Tgi declined to 37.5°C. A general linear model repeated-measures analysis of variance and independent t tests were calculated, with P < .05.

Main outcome measure(s)

Physical characteristics, maximal Tgi, time to reach 37.5°C, and cooling rate.

Results

Physical characteristics were different between groups. No differences existed in environmental measures or maximal Tgi (FBs = 39.12°C ± 0.39°C, CCs = 39.38°C ± 0.19°C; P = .12). Cooling times required to reach 37.5°C (FBs = 11.4 ± 4 minutes, CCs = 7.7 ± 0.06 minutes; P -1 ± 0.06°C·min-1, CCs = .255°C·min-1 ± 0.05°C·min-1; P < .002) were different. Strong correlations were found between cooling rate and body mass (r = -0.76, P < .001), total BSA (r = -0.74, P < .001), BSA/mass (r = 0.73, P < .001), LBM/mass (r = 0.72, P < .002), and LBM (r = -0.72, P < .002).

Conclusions

With cold-water immersion, the cooling rate in CCs (0.255°C·min-1) was greater than in FBs (0.156°C·min-1); however, both were considered ideal (≥0.155°C·min-1). Athletic trainers should realize that it likely takes considerably longer to cool large hyperthermic American-football players (>11 minutes) than smaller, leaner athletes (7.7 minutes). Cooling rates varied widely from 0.332°C·min-1 in a small runner to only 0.101°C·min-1 in a lineman, supporting the use of rectal temperature for monitoring during cooling.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.