Lanzamiento Enero 2027

Ensayo controlado aleatorizado2018

Low-level laser therapy with 940 nm diode laser on stability of dental implants: a randomized controlled clinical trial

Torkzaban P, Kasraei S, Torabi S, Farhadian M

Lasers in medical science · 29 citas

Cómo se estudió

Diseño
Ensayo controlado aleatorizado (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación independiente
Universidad u hospital
Vice Chancellor of Research, Hamadan University of Medical Sciences

Según 1 financiador declarado.

Publicación

Publicado
2017-10-29 · Lasers Med Sci · vol. 33 · número 2 · págs. 287–293
Editorial
Springer Science+Business Media
Citado
59 citas · más que el 92% de estudios similares · 3.2× el promedio de su campo
Impacto
Entre el 10 % más citado de su campo
Referencias
50 trabajos
Acceso
De pago
Áreas de investigación
Laser Applications in Dentistry and Medicine · Dental Implant Techniques and Outcomes · Scientific and Engineering Research Topics
Palabras clave
low-level laser therapy, dental implants, implant stability, 940 nm diode laser, implant stability quotient, bone regeneration, osteoblast activity
MeSH
humans, dental implants, osseointegration, time factors, adult, female, male, lasers, semiconductor, low-level light therapy

4 autores

  • Parviz Torkzaban🇮🇷Hamedan University of Medical Sciences
  • Shahin Kasraei🇮🇷 · autor de correspondenciaShahid Beheshti University; Shahid Beheshti University of Medical Sciences
  • Sara Torabi🇮🇷Zanjan University of Medical Sciences
  • Maryam Farhadian🇮🇷Hamedan University of Medical Sciences

Resumen

El texto original del estudio, en el idioma en que se publicó.

Low-level laser therapy (LLLT) is a non-invasive modality to promote osteoblastic activity and tissue healing. The aim of this study was to evaluate the efficacy of LLLT for improvement of dental implant stability. This randomized controlled clinical trial was performed on 80 dental implants placed in 19 patients. Implants were randomly divided into two groups (n = 40). Seven sessions of LLLT (940 nm diode laser) were scheduled for the test group implants during 2 weeks. Laser was irradiated to the buccal and palatal sides. The same procedure was performed for the control group implants with laser hand piece in "off" mode. Implant stability was measured by Osstell Mentor device in implant stability quotient (ISQ) value immediately after surgery and 10 days and 3, 6, and 12 weeks later. Repeated measures ANOVA was used to compare the mean ISQ values (implant stability) in the test and control groups. Statistical test revealed no significant difference in the mean values of implant stability between the test and control groups over time (P = 0.557). Although the mean values of implant stability changed significantly in both groups over time (P < 0.05). Although the trend of reduction in stability was slower in the laser group in the first weeks and increased from the 6th to 12th week, LLLT had no significant effect on dental implant stability.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.