Lanzamiento Enero 2027

Ensayo controlado aleatorizado2019Acceso abierto

Photobiomodulation by a 635nm Diode Laser on Peri-Implant Bone: Primary and Secondary Stability and Bone Density Analysis-A Randomized Clinical Trial

Matys J, Świder K, Grzech-Leśniak K, Dominiak M, Romeo U

BioMed research international · 38 citas

Cómo se estudió

Diseño
Ensayo controlado aleatorizado (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación independiente

Según la declaración de financiación del texto completo.

Publicación

Publicado
2019-04-22 · Biomed Res Int · vol. 2019 · págs. 1–8
Editorial
Hindawi Publishing Corporation
Citado
71 citas · más que el 97% de estudios similares · 6.0× el promedio de su campo
Impacto
Entre el 10 % más citado de su campo
Referencias
33 trabajos
Acceso
Acceso abierto (revista híbrida) · CC-BY
Áreas de investigación
Laser Applications in Dentistry and Medicine · Dental Implant Techniques and Outcomes · Dental Radiography and Imaging
Palabras clave
low-level laser therapy, dental implants, peri-implant bone, implant stability, primary stability, secondary stability, bone mineral density, peri-implantitis prevention, cone-beam computed tomography
MeSH
humans, dental implants, case-control studies, bone density, middle aged, female, male, lasers, semiconductor, cone-beam computed tomography, low-level light therapy

5 autores

  • Jacek Matys🇮🇹 · autor de correspondenciaSapienza University of Rome
  • Katarzyna Świder🇵🇱University of Wrocław; Wroclaw Medical University
  • Kinga Grzech‐Leśniak🇵🇱University of Wrocław; Wroclaw Medical University
  • Marzena Dominiak🇵🇱University of Wrocław; Wroclaw Medical University
  • Umberto Romeo🇮🇹Sapienza University of Rome

Resumen

El texto original del estudio, en el idioma en que se publicó.

Introduction

Various procedures in dental implantology are performed to enhance the bone healing process and implant stability. One of these methods can be a low-level laser therapy (LLLT).

Objectives

The aim of our study was to evaluate the stabilization (primary and secondary) and bone density in peri-implant zone after LLLT protocol using a 635 nm diode laser.

Material and methods

The research included 40 implants placed in the posterior region of a mandible in 24 patients (8 women and 16 man; age: 46.7 ± 8.7 years). The patients were randomly divided into 2 groups G1 (n=12, 18 implants) and G2 (n=12, 22 implants) according to the treatment procedure; G1 (test): 635 nm laser, with handpiece diameter: 8mm, output power: 100mW, spot area: 0.5024cm2, average power density: 199.04mW/cm2, continuous mode, dose: 4J per point (8J/cm2), time: 40 sec per point, 2 points (irradiation on a buccal and a lingual side of the alveolus/implant), and total energy per session 8J; G2 (control): no laser irradiation. The G1 (test) group's implants were irradiated according to the following protocol: 1 day before surgery, immediately after the surgery and 2, 4, 7, and 14 days after. The total energy after all therapeutic sessions was 48J. The implants stability was measured employing a Periotest device (Periotest Test Value: PTV) (measured immediately after the surgery, 7 days, 2 weeks, 4 weeks, and 2 and 3 months after the surgery) and the bone density using cone-beam computed tomography (grayscale value) (measured immediately after the surgery, 4 weeks and 12 weeks after the treatment).

Results

The average implant stability at different time points showed lower PTV value (higher stability) at 2nd and 4th week after 635 nm laser irradiation (G1) compared with a control (G2) group (p0.05). The mean grayscale value at the apical, middle, and cervical level of the titanium implants showed the reduction of pixel grayscale value after 2 weeks and was lower for the G1 group in contrast to the G2 group (p<0.01). The value of grayscale after 12 weeks was significantly higher at the middle and apical level of the implants in the G1group in contrast to the G2 group (p<0.01).

Conclusion

The application of the 635 nm diode laser enhanced secondary implant stability and bone density. However, to assess the impact of the LLLT on peri-implant bone with different bone densities, further well-controlled long-term trials on larger study groups are needed.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial (CC BY).

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.