Influence of low-level laser therapy on implant stability in implants placed in fresh extraction sockets: A randomized clinical trial
Lobato RPB, Kinalski MA, Martins TM, Agostini BA, Bergoli CD, Dos Santos MBF
Clinical implant dentistry and related research · 18 citas
Cómo se estudió
- Diseño
- Ensayo controlado aleatorizado (indexado por PubMed)
- Estudiado en
- Personas
- Resultado principal
- Marcadores de salud y funcionamiento
Quién lo pagó
- Financiación
- Financiación independiente
- Gobierno
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Según 1 financiador declarado.
Publicación
- Publicado
- 2020-04-24 · Clin Implant Dent Relat Res · vol. 22 · número 3 · págs. 261–269
- Editorial
- Wiley
- Citado
- 39 citas · más que el 97% de estudios similares · 5.9× el promedio de su campo
- Impacto
- Entre el 10 % más citado de su campo
- Referencias
- 39 trabajos
- Acceso
- De pago
- Áreas de investigación
- Dental Implant Techniques and Outcomes · Laser Applications in Dentistry and Medicine · Scientific and Engineering Research Topics
- Palabras clave
- low-level laser therapy, dental implants, implant stability, fresh extraction sockets, primary stability, osseointegration, GaAlAs laser, insertion torque, implant stability quotient, peri-implant soft tissue
- MeSH
- alveolar process, tooth socket, animals, humans, dental implants, dental implantation, endosseous, osseointegration, low-level light therapy
6 autores
- Renan Pablo Bittencourt Lobato🇧🇷Universidade Federal de Pelotas
- Mateus de Azevedo Kinalski🇧🇷Universidade Federal de Pelotas
- Thiago Marchi Martins🇧🇷Universidade Federal de Pelotas
- Bernardo Antônio Agostini🇧🇷Atitus Educação
- César Dalmolin Bergoli🇧🇷Universidade Federal de Pelotas
- Mateus Bertolini Fernandes dos Santos🇧🇷 · autor de correspondenciaUniversidade Federal de Pelotas
Resumen
El texto original del estudio, en el idioma en que se publicó.
Background
Low-level laser therapy (LLLT) has been suggested to improve primary stability at the early stages of osseointegration in animal models. However, there is still scarce evidence about its influence on implant stability in humans.
Purpose
To assess the influence of LLLT on implant stability in implants placed in fresh extraction sockets.
Material and methods
A randomized controlled trial was designed according to the SPIRIT guidelines and is reported following the CONSORT. Patients were randomly allocated according to control or LLLT groups. LLLT consisted in the application of GaAlAs laser (808 nm, avg. power density: 50 mW, circular spot diameter and area: 0.71 cm/0.4cm2 ) applied in six points in contact mode with peri-implant soft tissue (1.23 minutes in each point of application; dose per point 11 J) before bone perforation and after suturing. The total dose resulted in 66 J per application moment. This LLLT protocol was applied only in the dental implant placement session. Implant stability was by ISQ at implant placement (T0 ) and the abutment selection (Ta ). Digital radiographs for T0 and Ta were used to assess the distance between the implant platform and alveolar bone crest, in millimeters. T-test and Shapiro-Wilk test were used to analyze data between groups using the implant as a unit of analysis.
Results
Fifty implants were placed in 44 patients. The insertion torque ranged from 15 to 60 N.cm (mean 35.64 ± 13.34). Two implants of the LLLT and one of the control groups were lost to follow-up and one implant of the control group failed to osseointegrate (4.3%). ISQ at T0 ranged from 17 to 79 (mean 59.33 ± 13.05) and from 40 to 89 (mean 66.46 SD ± 11.56) at Ta . No differences were observed when comparing the groups with ISQ difference (P = .433) or radiographical peri-implant alterations (P = .261).
Conclusions
LLLT did not influence implant stability in implants placed in fresh extraction sockets when assessed at healing abutment installation.
Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.