Lanzamiento Enero 2027

Ensayo controlado aleatorizado2020

Influence of low-level laser therapy on implant stability in implants placed in fresh extraction sockets: A randomized clinical trial

Lobato RPB, Kinalski MA, Martins TM, Agostini BA, Bergoli CD, Dos Santos MBF

Clinical implant dentistry and related research · 18 citas

Cómo se estudió

Diseño
Ensayo controlado aleatorizado (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación independiente
Gobierno
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Según 1 financiador declarado.

Publicación

Publicado
2020-04-24 · Clin Implant Dent Relat Res · vol. 22 · número 3 · págs. 261–269
Editorial
Wiley
Citado
39 citas · más que el 97% de estudios similares · 5.9× el promedio de su campo
Impacto
Entre el 10 % más citado de su campo
Referencias
39 trabajos
Acceso
De pago
Áreas de investigación
Dental Implant Techniques and Outcomes · Laser Applications in Dentistry and Medicine · Scientific and Engineering Research Topics
Palabras clave
low-level laser therapy, dental implants, implant stability, fresh extraction sockets, primary stability, osseointegration, GaAlAs laser, insertion torque, implant stability quotient, peri-implant soft tissue
MeSH
alveolar process, tooth socket, animals, humans, dental implants, dental implantation, endosseous, osseointegration, low-level light therapy

6 autores

  • Renan Pablo Bittencourt Lobato🇧🇷Universidade Federal de Pelotas
  • Mateus de Azevedo Kinalski🇧🇷Universidade Federal de Pelotas
  • Thiago Marchi Martins🇧🇷Universidade Federal de Pelotas
  • Bernardo Antônio Agostini🇧🇷Atitus Educação
  • César Dalmolin Bergoli🇧🇷Universidade Federal de Pelotas
  • Mateus Bertolini Fernandes dos Santos🇧🇷 · autor de correspondenciaUniversidade Federal de Pelotas

Resumen

El texto original del estudio, en el idioma en que se publicó.

Background

Low-level laser therapy (LLLT) has been suggested to improve primary stability at the early stages of osseointegration in animal models. However, there is still scarce evidence about its influence on implant stability in humans.

Purpose

To assess the influence of LLLT on implant stability in implants placed in fresh extraction sockets.

Material and methods

A randomized controlled trial was designed according to the SPIRIT guidelines and is reported following the CONSORT. Patients were randomly allocated according to control or LLLT groups. LLLT consisted in the application of GaAlAs laser (808 nm, avg. power density: 50 mW, circular spot diameter and area: 0.71 cm/0.4cm2 ) applied in six points in contact mode with peri-implant soft tissue (1.23 minutes in each point of application; dose per point 11 J) before bone perforation and after suturing. The total dose resulted in 66 J per application moment. This LLLT protocol was applied only in the dental implant placement session. Implant stability was by ISQ at implant placement (T0 ) and the abutment selection (Ta ). Digital radiographs for T0 and Ta were used to assess the distance between the implant platform and alveolar bone crest, in millimeters. T-test and Shapiro-Wilk test were used to analyze data between groups using the implant as a unit of analysis.

Results

Fifty implants were placed in 44 patients. The insertion torque ranged from 15 to 60 N.cm (mean 35.64 ± 13.34). Two implants of the LLLT and one of the control groups were lost to follow-up and one implant of the control group failed to osseointegrate (4.3%). ISQ at T0 ranged from 17 to 79 (mean 59.33 ± 13.05) and from 40 to 89 (mean 66.46 SD ± 11.56) at Ta . No differences were observed when comparing the groups with ISQ difference (P = .433) or radiographical peri-implant alterations (P = .261).

Conclusions

LLLT did not influence implant stability in implants placed in fresh extraction sockets when assessed at healing abutment installation.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.