Lanzamiento Enero 2027

Ensayo controlado aleatorizado2024

The application of heating film to hands reduces the decline in manual dexterity performance associated with cold exposure

Wang G, Fan J, Yue T, Gao X, Zhang T, Hurr C

European journal of applied physiology · 2 citas

Cómo se estudió

Diseño
Ensayo controlado aleatorizado (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación independiente
Gobierno
National Research Foundation of Korea
Subvenciones
National Research Foundation of Korea (RS-2023-00243082)

Según 1 financiador declarado.

Publicación

Publicado
2024-05-31 · Eur J Appl Physiol · vol. 124 · número 10 · págs. 3095–3103
Editorial
Springer Science+Business Media
Citado
3 citas · más que el 69% de estudios similares · 0.7× el promedio de su campo
Referencias
20 trabajos
Acceso
De pago
Áreas de investigación
Thermoregulation and physiological responses · Thermal Regulation in Medicine · Infrared Thermography in Medicine
Palabras clave
cold exposure, manual dexterity, finger temperature, cutaneous vascular conductance, fine motor performance, cognitive function, Stroop task, Grooved Pegboard Test, cold environment
MeSH
hand, fingers, humans, cross-over studies, psychomotor performance, motor skills, heating, skin temperature, adult, female, male, cold temperature, hot temperature, young adult

6 autores

  • Gang Wang🇨🇳🇰🇷Xinyang Normal University; Jeonbuk National University
  • Junli Fan🇰🇷Jeonbuk National University
  • Ting Yue🇰🇷Jeonbuk National University
  • Xinpeng Gao🇰🇷Jeonbuk National University
  • Tingran Zhang🇰🇷Jeonbuk National University
  • Chansol Hurr🇰🇷 · autor de correspondenciaJeonbuk National University

Resumen

El texto original del estudio, en el idioma en que se publicó.

Purpose

Exposure to cold temperatures decreases finger temperature (Tfing) and dexterity. Decreased manual function and dexterity can be serious safety risks, especially in tasks that require fine motor movements that must be performed outdoors. The aim of this study was to determine whether hand heating with a minimal power requirement (14.8 W) results in a smaller reduction in Tfing and manual dexterity performance during mild cold exposure compared to a non-heated control condition.

Methods

In a randomized crossover design, twenty-two healthy participants were exposed to a moderately cold environment (5 ºC) for 90 min. One condition had no intervention (CON), while the other had the palmar and dorsal hands heated (HEAT) by using electric heating films. Tfing and cutaneous vascular conductance (CVC) were continuously monitored using laser Doppler flowmetry. Manual dexterity performance and cognitive function were assessed by the Grooved Pegboard Test (GPT) and Stroop Color-Word (SCW) test, respectively, during the baseline period and every 30 min during the cold exposure.

Results

After the cold exposure, Tfing was higher in HEAT relative to CON (CON 9.8 vs. HEAT 13.7 ºC, p 0.05 for all). Cognitive function was similar between two conditions (p > 0.05 for all).

Conclusion

The proposed hand heating method offers a practical means of heating fingers to maintain dexterity throughout prolonged cold exposure.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.