MiniMed 780G System Use in Type 1 Diabetes During Ramadan Intermittent Fasting: A Systematic Literature Review and Expert Recommendations

Elbarbary N, Alguwaihes A, Zarif H, Hassanein M, Deeb A, Petrovski G, Al Dahash R, Alamoudi R, Hussain S, Ibrahim M, Shaikh S, Zainudin SB, Chaar W, van den Heuvel T, Al-Sofiani ME

Diabetes technology & therapeutics · 7 citas

Etiquetas de revisión

Financiación no declarada

Datos neutrales que nuestra revisión registró sobre cómo se hizo este estudio. Describen el método, nunca si nos gusta el resultado.

Cómo se estudió

Diseño
Revisión sistemática (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación no declarada

Publicación

Publicado
2024-07-25 · Diabetes Technol Ther · vol. 27 · número 1 · págs. 72–85
Editorial
Mary Ann Liebert, Inc.
Citado
12 citas · más que el 77% de estudios similares · 1.1× el promedio de su campo
Referencias
35 trabajos
Acceso
Acceso abierto (revista híbrida) · CC-BY
Áreas de investigación
Diabetes Management and Research · Dietary Effects on Health · Diabetes Management and Education
Palabras clave
MiniMed 780G, type 1 diabetes, Ramadan fasting, intermittent fasting, artificial pancreas, continuous glucose monitoring, glycemic control, hypoglycemia, diabetic ketoacidosis, time in range
MeSH
humans, diabetes mellitus, type 1, hypoglycemia, insulin, blood glucose, hypoglycemic agents, insulin infusion systems, fasting, islam, intermittent fasting

15 autores

  • Nancy Samir Elbarbary🇪🇬Ain Shams University
  • Abdullah M. Alguwaihes🇸🇦King Saud University
  • HAWAZEN A. ZARIF🇸🇦King Saud bin Abdulaziz University for Health Sciences; King Abdulaziz Medical City; National Guard Health Affairs
  • Mohammed Hassanein🇦🇪Dubai Hospital; Mohammed Bin Rashid University of Medicine and Health Sciences
  • Asma Deeb🇦🇪Khalifa University of Science and Technology; Sheikh Shakhbout Medical City
  • Goran Petrovski🇶🇦🇺🇸Sidra Medical and Research Center; Weill Cornell Medical College in Qatar; Weill Cornell Medicine
  • Raed Aldahash🇸🇦King Saud bin Abdulaziz University for Health Sciences; King Abdulaziz Medical City; National Guard Health Affairs
  • Reem Al Amoudi🇸🇦King Saud bin Abdulaziz University for Health Sciences; King Abdulaziz Medical City; National Guard Health Affairs
  • Sufyan Hussain🇬🇧King's College London; Guy's and St Thomas' NHS Foundation Trust; Kings Health Partners
  • Mahmoud Ashraf Ibrahim
  • Shehla Sajid Shaikh🇮🇳Saifee Hospital
  • Sueziani Binte Zainudin🇸🇬Sengkang General Hospital
  • Wael Chaar
  • Tim R. A. van den Heuvel🇨🇭Medtronic (Switzerland)
  • Mohammed E. Al‐Sofiani🇺🇸🇸🇦Johns Hopkins University; King Saud University

Resumen

El texto original del estudio, en el idioma en que se publicó.

This article offers a systematic literature review (SLR) on the use of the MiniMed 780G automated insulin delivery system (MM780G) in people with type 1 diabetes (PwT1D) during Ramadan intermittent fasting. It also presents consensus recommendations on the use of MM780G during the Ramadan period. The SLR was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses methodology. The recommendations resulted from a consensus-forming process involving a panel of experts. The process considered evidence found in the SLR as well as the expert opinions. In total, six studies were included in the SLR. The evidence and expert opinions led to recommendations related to (a) pre-Ramadan counseling of MM780G users who plan to fast; (b) suggested MM780G settings, meal announcement strategy, and safety aspects during Ramadan (including a contingency plan); and (c) post-Ramadan transition into and out of Eid-al-Fitr festivities. The SLR findings showed that the MM780G maintains glycemic control at target in PwT1D during Ramadan (meeting continuous glucose monitoring-based clinical targets proposed by the International Consensus on Time-in-Range) while ensuring low rates of hypoglycemia and diabetic ketoacidosis. Automated insulin delivery also helps PwT1D fast more days of Ramadan compared with users of other less advanced modalities of treatment. Pre-Ramadan guidance on specific aspects of the MM780G along with the International Diabetes Federation and Diabetes and Ramadan International Alliance counseling guidelines is recommended. There is still a challenge with post-Iftar hyperglycemia, which could potentially be mitigated by following the recommendations outlined in this article.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.