Lanzamiento Enero 2027

Estudio2026Acceso abierto

Acute measurement of flow-mediated dilation following passive heating in adults: The confounding role of altered shear stress and baseline vasodilation

Menzies C, Clarke ND, Steward CJ, Thake CD, Pugh CJA, Cullen T

Physiological reports · 1 cita

Cómo se estudió

Diseño
Ensayo clínico controlado (clasificado por nuestro filtro de IA)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación independiente
Universidad u hospital
Coventry University

Según 1 financiador declarado y la declaración de financiación del texto completo.

Publicación

Publicado
2026-02-01 · Physiol Rep · vol. 14 · número 4 · pág. e70723
Editorial
Wiley
Citado
0 citas · más que el 12% de estudios similares · 0.0× el promedio de su campo
Referencias
28 trabajos
Acceso
Acceso abierto (revista) · CC-BY
Áreas de investigación
Thermoregulation and physiological responses · Cardiovascular Health and Disease Prevention · Infrared Thermography in Medicine
Palabras clave
Brachial artery, Vasodilation, Confounding, Dilation (metric space), Occlusion, Baseline (sea), Acute exposure, Allometry
MeSH
brachial artery, humans, regional blood flow, vasodilation, stress, mechanical, adult, female, male, hot temperature, young adult

6 autores

  • Campbell Menzies🇬🇧 · autor de correspondenciaUniversity of Nottingham; Coventry University
  • Neil David Clarke🇬🇧Birmingham City University
  • Charles James Steward🇬🇧University of Nottingham; Coventry University
  • C. Douglas Thake🇬🇧Coventry University
  • Christopher J. A. Pugh🇬🇧Cardiff Metropolitan University
  • Tom Cullen🇬🇧Coventry University

Resumen

El texto original del estudio, en el idioma en que se publicó.

Changes in flow-mediated dilation (FMD) following acute heating are not well understood, appear protocol-specific, and may be better understood by additional measures of acute vasoactivity. This study investigated FMD responses before and after three different 30-min hot-water immersion conditions (40°C-Shoulder, 42°C-Waist, and 40°C-Waist) in 22 adults. Brachial artery diameter was recorded at baseline (Dbase), during the final 30 s of occlusion (Docc), and at peak post-occlusion (Dpeak). Allometrically scaled FMD%, and changes in diameter during occlusion (OIV), and from end-occlusion to peak diameter (FMDDocc) were calculated. Pre-occlusion shear rate was greater post-immersion in 40-Shoulder (p base increased (Δ0.4 ± 0.2 mm, p base (rrm = -0.47, p = 0.001). OIV% was the only vasoactivity metric to statistically differentiate between all conditions post-immersion (40°C-Shoulder: -8.1 ± 4.9%. 42°C-Waist: -3.0 ± 5.3%. 40°C-Waist: 1.1 ± 4.1%. p < 0.001). Post-heating FMD is confounded by heat-induced increases in baseline diameter, even after allometric scaling, while OIV% may provide complementary insight into acute vasoactivity following passive heating.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial (CC BY).

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.