Effectiveness of GV20-based wearable low-level laser acupoint therapy for pain on head
Lei WF, Sadiq A, Cui ZY, Wu XB, Lee SD
Lasers in medical science · 1 cita
Cómo se estudió
- Diseño
- Ensayo controlado aleatorizado (indexado por PubMed)
- Estudiado en
- Personas
- Resultado principal
- Marcadores de salud y funcionamiento
Quién lo pagó
- Financiación
- Financiación independiente
- Universidad u hospital
- China Medical University
Según 1 financiador declarado y la declaración de financiación del texto completo.
Publicación
- Publicado
- 2026-05-07 · Lasers Med Sci · vol. 41 · número 1
- Editorial
- Springer Science+Business Media
- Citado
- 1 cita · más que el 93% de estudios similares · 4.6× el promedio de su campo
- Impacto
- Entre el 10 % más citado de su campo
- Referencias
- 17 trabajos
- Acceso
- Acceso abierto (revista híbrida) · CC-BY
- Áreas de investigación
- Laser Applications in Dentistry and Medicine · Acupuncture Treatment Research Studies · Pain Management and Treatment
- Palabras clave
- low-level laser therapy, acupoint therapy, wearable devices, temporal headache, 650 nm laser, sham acupoint, analgesia
- MeSH
- head, humans, headache, pain measurement, treatment outcome, acupuncture points, adult, female, male, young adult, low-level light therapy, wearable electronic devices
5 autores
- Wen-Fang Lei🇹🇼China Medical University
- Arslan Sadiq🇹🇼China Medical University
- Zhen-Yang Cui🇨🇳Weifang Medical University
- Xubo Wu🇨🇳Pudong New Area People's Hospital
- Shin‐Da Lee🇹🇼 · autor de correspondenciaChina Medical University
Resumen
El texto original del estudio, en el idioma en que se publicó.
The effectiveness of GV20-based Wearable Low-level Laser Acupoint Therapy for pain on right temporal head was investigated. The study was designed as a triple-blinded, randomized controlled clinical trial. The deep pressure pain targeted by 300g monofilament and Visual Analog Scale (VAS, 0-10) scores on right temporal head were assessed were randomly assigned to wearable LLLAT (650 nm, 5 mW, 30 min, about 9 joule each acupoint) on Baihui (GV20) with four Sishencong (EX-HN1) or sham group (n=24 vs 24). The mean VAS pain scores in wearable LLLAT group after GV20 with EX-HN1 acupoint treatment were significantly decreased comparing with sham group. This trial suggested that wearable Low-level Laser Acupoint Therapy 650 nm 5 mW for 30 min each acupoint simultaneously could effectively reduce deep pressure pain on temporal head.
Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial (CC BY).
Confianza de la comunidad
Cargando…
¿Cuánto confías en los hallazgos de este estudio?
Comentarios
¿Algo está mal aquí?
Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.
Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.