Lanzamiento Enero 2027

Estudio2026Acceso abierto

Short-Term Effects of Low-Level Red-Light Therapy on Central Retinal Function: A Combined Pattern ERG and Photopic ERG Study

Qasim M, Fernandes P, Jorge J

Vision (Basel, Switzerland) · 0 citas

Cómo se estudió

Diseño
Ensayo clínico controlado (clasificado por nuestro filtro de IA)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación independiente
Universidad u hospital
Universidade do Minho
Gobierno
Fundação para a Ciência e a Tecnologia
Subvenciones
Fundação para a Ciência e a Tecnologia (UID/04650); Fundação para a Ciência e a Tecnologia (UID/04650/2025); Fundação para a Ciência e a Tecnologia (04650/2025)

Según 2 financiadores declarados y la declaración de financiación del texto completo.

Publicación

Publicado
2026-05-08 · Vision (Basel) · vol. 10 · número 2 · pág. 26
Editorial
Multidisciplinary Digital Publishing Institute
Citado
0 citas · más que el 41% de estudios similares · 0.0× el promedio de su campo
Referencias
0 trabajos
Acceso
Acceso abierto (revista) · CC-BY
Áreas de investigación
Laser Applications in Dentistry and Medicine · Ophthalmology and Visual Impairment Studies · Retinal Diseases and Treatments
Palabras clave
Photopic vision, Electroretinography, Erg, Retinal, Retina, Electrophysiology

3 autores

  • Muhammad Qasim🇵🇹 · autor de correspondenciaCentro de Física das Universidades do Minho e do Porto; University of Minho
  • Paulo Fernandes🇵🇹 · autor de correspondenciaCentro de Física das Universidades do Minho e do Porto; University of Minho
  • Jorge Jorge🇵🇹Centro de Física das Universidades do Minho e do Porto; University of Minho

Resumen

El texto original del estudio, en el idioma en que se publicó.

Background: Low-level red-light therapy (RLRT) has emerged as a potential therapy in myopia management. However, its effects on retinal structure and function following repeated exposure remain incompletely understood. Purpose: To evaluate the short-term effects of RLRT on central retinal function in myopes and non-myopes using retinal electrophysiology and structural parameters. Methods: Thirty-six subjects underwent RLRT exposures. Retinal function was assessed using pattern electroretinography (PERG) and photopic full-field electroretinography (Photopic 3.0 ERG). Structural measurements, including axial length (AL), obtained with an optical biometer and choroidal thickness (CT), were measured using MOPTIM 3000. Outcomes were compared between baseline and post-RLRT conditions (single 3 min and single 1 min exposure), across refractive groups, and correlated with AL and CT. This study was conducted at the University of Minho in accordance with the Declaration of Helsinki. Results: In myopic subjects, PERG N35-P50 amplitude significantly increased after 3 min of RLRT (baseline:0.88 ± 0.21 µV; post: 1.40 ± 0.25 µV; p = 0.013), whereas no significant changes were observed in non-myopes (baseline: 1.32 ± 0.19 µV; post: 1.39 ± 0.21 µV; p = 0.47). Latencies remained stable across all groups (p > 0.05). No significant correlations were found between PERG and AL (ρ = -0.18, p = 0.44) or CT (ρ = 0.12, p = 0.52). Photopic 3.0 ERG showed an increase in b-wave amplitude after 3 min of RLRT in myopes (Δ = +2.42 µV, p = 0.06), but not in non-myopes. In myopes, AL was negatively correlated with post-therapy latency (ρ = -0.624, p = 0.060), while CT showed strong correlations with photopic a-wave responses after 1 min RLRT (CT vs. latency: ρ = -0.873, p = 0.010; CT vs. amplitude: ρ = 0.821, p = 0.034). Conclusions: Short-term exposure to RLRT, particularly at 3 min, enhances PERG and Photopic ERG responses in myopic subjects, suggesting transient improvements in retinal function with differential effects between refractive groups.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial (CC BY).

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.