Lanzamiento Enero 2027

Estudio2026Acceso abierto

Identifying the interaction between skin temperature, maintained thermal comfort, and conduit artery shear rate through limb passive heating

Schabbehard EL, Nessler S, Lawley JS

Physiological reports · 1 cita

Cómo se estudió

Diseño
Ensayo clínico controlado (clasificado por nuestro filtro de IA)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación independiente

Según la declaración de financiación del texto completo.

Publicación

Publicado
2026-06-01 · Physiol Rep · vol. 14 · número 11 · pág. e70923
Editorial
Wiley
Citado
1 cita · más que el 96% de estudios similares · 5.4× el promedio de su campo
Impacto
Entre el 10 % más citado de su campo
Referencias
47 trabajos
Acceso
Acceso abierto (revista) · CC-BY
Áreas de investigación
Infrared Thermography in Medicine · Cardiovascular Health and Disease Prevention · Thermoregulation and physiological responses
Palabras clave
Shear (geology), Shear rate, Femoral artery, Thermal, Brachial artery, Skin temperature, Superficial femoral artery
MeSH
arm, brachial artery, femoral artery, humans, skin temperature, regional blood flow, adult, female, male, hot temperature, young adult, thermal comfort

3 autores

  • Eva‐Lotte Schabbehard🇦🇹Universität Innsbruck
  • Stephanie Nessler🇦🇹Universität Innsbruck
  • Justin S. Lawley🇦🇹 · autor de correspondenciaUniversität Innsbruck

Resumen

El texto original del estudio, en el idioma en que se publicó.

Cardiovascular disease remains the leading cause of mortality. One reason is vascular dysfunction leading to pathological shear rate pattern. Limb passive heating (LPH) is a non-pharmacological intervention, improving vascular health by enhancing shear rate. As LPH is intended for long-term application, it is essential to identify a tolerable heating intensity that effectively reduces retrograde and increases antegrade shear rate without causing thermal discomfort. This study aimed to determine an LPH intensity that balances effective shear rate levels with thermal comfort. In 15 healthy participants (26 ± 3 years), LPH was applied to the right arm and leg targeting skin temperatures of resting baseline, 35°C and 40°C, while the contralateral limbs were maintained at 30°C as controls. After 10 min of steady-state heating, brachial and superficial femoral retro-, and antegrade shear rates, and local thermal comfort were assessed. Brachial artery: antegrade shear rate (35°C, p = 0.006; 40°C, p < 0.0001) increased, retrograde shear rate (p = 0.006) reduced at 40°C, and local arm thermal comfort was 8 ± 1. Femoral artery: antegrade shear rate (35°C, p < 0.0001; 40°C, p < 0.0001) and retrograde shear rate (35°C, p = 0.001; 40°C, p < 0.0001) altered significantly compared to controls, with local leg thermal comfort at 9 ± 1. These findings suggest through statistical interpolation, on average a skin temperature of approximately 38°C is perceived as thermally comfortable during acute LPH.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial (CC BY).

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.