Lanzamiento Enero 2027

Ensayo controlado aleatorizado1995Financiación no declarada

A clinical investigation of the efficacy of low level laser therapy in reducing orthodontic postadjustment pain

Lim HM, Lew KK, Tay DK

American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 130 citas

Etiquetas de revisión

Financiación no declarada

Datos neutrales que nuestra revisión registró sobre cómo se hizo este estudio. Describen el método, nunca si nos gusta el resultado.

Cómo se estudió

Diseño
Ensayo controlado aleatorizado (indexado por PubMed)
Estudiado en
Personas
Resultado principal
Marcadores de salud y funcionamiento

Quién lo pagó

Financiación
Financiación no declarada

Publicación

Publicado
1995-12-01 · Am J Orthod Dentofacial Orthop · vol. 108 · número 6 · págs. 614–622
Editorial
Elsevier BV
Citado
239 citas · más que el 65% de estudios similares · 0.4× el promedio de su campo
Referencias
68 trabajos
Acceso
De pago
Áreas de investigación
Laser Applications in Dentistry and Medicine · Orthodontics and Dentofacial Orthopedics · Dental Anxiety and Anesthesia Techniques
Palabras clave
low-level laser therapy, orthodontic pain, analgesia, elastomeric separators, diode laser, treatment duration, visual analogue scale
MeSH
humans, pain, arsenicals, gallium, aluminum, rubber, placebos, pain measurement, analgesia, double-blind method, orthodontic appliances, time factors, adult, statistics as topic, laser therapy, tooth movement techniques

3 autores

  • Hong-Meng Lim🇸🇬National University of Singapore
  • Kenneth K. Lew
  • David K.L. Tay

Resumen

El texto original del estudio, en el idioma en que se publicó.

Low level laser therapy (LLLT) has been shown to produce analgesic effects in many clinical applications. The aim of this clinical study was to test the efficacy of LLLT in controlling orthodontic postadjustment pain. Thirty-nine volunteers were selected for this study that used a double-blind design with placebo control. Elastomeric separators were placed at the proximal contacts of one premolar in each quadrant of the dentition to induce orthodontic pain. The tip of a 30 mW gallium-arsenide-aluminium (830 nm) diode laser probe was then placed at the buccal gingiva and directed at the middle third of the root. Three different treatment durations of 15, 30, and 60 seconds and one placebo treatment of 30 seconds were tested within each subject. The study was conducted over 5 days, and the visual analogue scale (VAS) was used to quantify the pain experienced by the subjects before and after laser applications for each day. Analysis of the VAS median scores showed that teeth exposed to laser treatment had lower levels of pain as compared with those with the placebo treatment. However, nonparametric statistical analysis of the data showed that the differences between treatments and placebo within each subject were not statistically significant.

Resumen vía Europe PMC. Los derechos de autor siguen siendo de los autores o la editorial.

Confianza de la comunidad

Cargando…

¿Cuánto confías en los hallazgos de este estudio?

0 · nada10 · totalmente

Comentarios

¿Algo está mal aquí?

Señala este estudio si su información, etiquetas o financiación parecen incorrectas. Un editor revisa cada señalamiento.

Información educativa sobre investigación publicada. No es consejo médico ni una recomendación para empezar o dejar nada.